Interactive practical
EMF and internal resistance
Vary the external load, measure terminal potential difference and current, then determine emf and internal resistance from a straight-line graph.
Open interactive simulationA-Level Physics
EMF and internal resistance
CCEA 1210 — matched to your course.
These revision notes are free. Premium unlocks the full question and retrieval-card bank for this topic.
Sign in to save this revision for later.
Revision hub
At a glance
Practical focus
- Vary current and use terminal potential difference data to determine cell emf and internal resistance.
Practical method
Aim
Determine the emf and internal resistance of a cell from a graph of terminal p.d. against current.
Variables
Independent variable: load resistance (and so current)
Dependent variable: terminal p.d.
Control variables: the same cell; short readings to avoid the cell running down.
Apparatus
- Cell
- Variable resistor (or resistance box)
- Ammeter
- High-resistance voltmeter
- Switch
- Protective resistor
Method
- Connect the cell in series with the ammeter, variable resistor, protective resistor and switch; connect the voltmeter across the cell.
- Close the switch briefly and record V and I. Open it between readings.
- Repeat for at least six settings of the variable resistor.
- Plot V against I. From V = ε − Ir, the intercept is ε and the gradient is −r.
Sample results
Single cell.
| I / A | V / V |
|---|---|
| 0.10 | 1.47 |
| 0.20 | 1.39 |
| 0.30 | 1.31 |
| 0.40 | 1.23 |
| 0.50 | 1.15 |
Analysis
V falls linearly with I. Intercept = 1.55 V = ε; gradient = −0.80 V A⁻¹, so r = 0.80 Ω.
Uncertainty
Voltmeter ±0.01 V and ammeter ±0.01 A give scatter of a few per cent. Using steepest and shallowest lines gives r = 0.80 ± 0.05 Ω.
Errors and improvements
| Problem | Effect | Improvement |
|---|---|---|
| Cell running down | V drifts | Take readings quickly; open the switch between them |
| Cell warming | r changes | Keep currents modest |
| Voltmeter draws current | V slightly low | Use a high-resistance digital voltmeter |
Risk assessment
| Hazard | Risk | Control measure |
|---|---|---|
| Short-circuiting the cell | Overheating | Include a protective resistor |
| Hot wires | Burns | Avoid large currents |
Common mistakes
- Reading r as the gradient without the minus sign.
- Connecting the voltmeter across the load only.
- Leaving the switch closed.
Worked analysis
From the graph: ε = 1.55 V. At I = 0.40 A, V = 1.23 V, so lost volts = 0.32 V and r = \(\dfrac{0.32}{0.40}\) = 0.80 Ω.
Common misconception
Emf is not a force; it is the energy supplied per coulomb, equal to the terminal p.d. only when no current flows.
Assessment coverage
Practice this practical
2 questions available, worth 4 marks in total.
Retrieval cards
What is emf?
Energy supplied per unit charge by a source.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
How this practical fits your course
The label below uses the wording from your course specification.
- CCEA 1210 — Specification experiment: Appendix 4 experiment 15 – e.m.f. and internal resistance of a battery. Appendix 4 specifies determination of battery e.m.f. and internal resistance. Checked 18 September 2026. View official course source