Interactive practical
Resistance of a metal wire against temperature
Read a thermometer and ohmmeter during heating and cooling, subtract lead resistance and determine the temperature coefficient at 20 °C.
Open interactive simulationA-Level Physics
Resistance of a metal wire against temperature
Eduqas A420QS — matched to your course.
These revision notes are free. Premium unlocks the full question and retrieval-card bank for this topic.
Sign in to save this revision for later.
Revision hub
At a glance
Practical focus
- Measure how the resistance of a metal conductor changes with temperature.
Practical method
Aim
Investigate how the resistance of a metal wire varies with temperature and find its temperature coefficient.
Variables
Independent variable: temperature
Dependent variable: resistance
Control variables: the same coil of wire; small measuring current.
Apparatus
- Coil of copper wire in a test tube
- Water bath with kettle and ice
- Thermometer
- Ohmmeter or ammeter–voltmeter circuit
- Stirrer
Method
- Place the coil in a test tube of oil (or water if insulated) in a water bath with a thermometer.
- Measure the resistance at 0 °C using ice water.
- Heat the bath in steps of 20 °C, stirring and waiting for a steady resistance reading at each temperature.
- Plot R against temperature θ: R = R₀(1 + αθ), so the gradient is R₀α.
Sample results
Copper coil; small current from the ohmmeter.
| θ / °C | R / Ω |
|---|---|
| 0 | 10.00 |
| 20 | 10.78 |
| 40 | 11.56 |
| 60 | 12.34 |
| 80 | 13.12 |
Analysis
R increases linearly with temperature, with gradient 0.039 Ω °C⁻¹ and R₀ = 10.00 Ω. α = \(\dfrac{0.039}{10.00}\) = 3.9 × 10⁻³ °C⁻¹, the accepted value for copper. Increased lattice vibrations scatter conduction electrons more often.
Uncertainty
Resistance is read to ±0.01 Ω (0.1%) and temperature to ±0.5 °C. The main uncertainty is the coil lagging the bath temperature.
Errors and improvements
| Problem | Effect | Improvement |
|---|---|---|
| Coil lags the bath temperature | R read at the wrong temperature | Stir and wait for steady readings |
| Self-heating from the measuring current | R too high | Use a small current |
| Resistance of leads | Constant offset | Measure lead resistance and subtract |
Risk assessment
| Hazard | Risk | Control measure |
|---|---|---|
| Hot water | Scalds | Handle carefully |
| Electricity near water | Shock | Low voltage; keep connections dry |
Common mistakes
- Reading temperature before thermal equilibrium.
- Ignoring the lead resistance.
- Treating α as the gradient without dividing by R₀.
Worked analysis
Gradient = \(\dfrac{13.12 - 10.00}{80}\) = 0.039 Ω °C⁻¹. α = \(\dfrac{\text{gradient}}{R_{0}}\) = \(\dfrac{0.039}{10.00}\) = 3.9 × 10⁻³ °C⁻¹.
Common misconception
Metals have higher resistance when hot because electrons collide more often with vibrating ions, not because there are fewer electrons.
Assessment coverage
Practice this practical
2 questions available, worth 4 marks in total.
Retrieval cards
How does metal resistance vary with temperature?
Increases roughly linearly.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
How this practical fits your course
The label below uses the wording from your course specification.
- Eduqas A420QS — Specified practical work: Specified practical work – Investigation of the variation of resistance with temperature for a metal wire. The specification requires measurement of how a metal wire's resistance varies with temperature. Checked 18 September 2026. View official course source