Interactive practical
Thermistor calibration and a potential-divider thermostat
Measure heating and cooling curves, calibrate an NTC thermistor and set a potential-divider thermostat.
Open interactive simulationA-Level Physics
Calibrating a thermistor thermostat
OCR H556 — matched to your course.
These revision notes are free. Premium unlocks the full question and retrieval-card bank for this topic.
Sign in to save this revision for later.
Revision hub
At a glance
Practical focus
- Calibrate a thermistor in a potential-divider circuit and relate output potential difference to temperature.
Practical method
Aim
Calibrate a thermistor in a potential divider as a thermometer and use it to set a thermostat.
Variables
Independent variable: temperature
Dependent variable: output p.d. of the potential divider
Control variables: supply p.d.; fixed resistor value.
Apparatus
- NTC thermistor
- Fixed resistor (or variable resistor)
- 6.0 V supply
- Voltmeter
- Beaker of water and kettle/ice
- Thermometer
- Stirrer
Method
- Build a potential divider: thermistor and fixed resistor in series across the supply, voltmeter across the fixed resistor.
- Place the thermistor and a thermometer in water; heat or cool it and stir.
- Record the output p.d. at temperatures from 0 °C to 80 °C.
- Plot a calibration curve of output p.d. against temperature.
- To make a thermostat, choose the fixed resistor so the output crosses a switching level (for example 3.0 V) at the required temperature.
Sample results
6.0 V supply, fixed resistor 2.2 kΩ, output across the fixed resistor.
| Temperature / °C | Thermistor R / kΩ | \(V_{\text{out}}\) / V |
|---|---|---|
| 0 | 9.8 | 1.10 |
| 20 | 4.5 | 1.97 |
| 40 | 2.2 | 3.00 |
| 60 | 1.2 | 3.88 |
| 80 | 0.7 | 4.55 |
Analysis
As temperature rises the thermistor's resistance falls, so a larger share of the 6.0 V appears across the fixed resistor. The calibration curve is non-linear; it is most sensitive near 40 °C, where the thermistor resistance equals the fixed resistor.
Uncertainty
The thermometer reads to ±0.5 °C and the thermistor lags behind the water temperature; stirring and waiting for a steady reading reduce the lag.
Errors and improvements
| Problem | Effect | Improvement |
|---|---|---|
| Thermistor not at water temperature | Readings lag | Stir and wait for steady readings |
| Self-heating of the thermistor | Temperature reads high | Use a small current |
| Water evaporating at high temperature | Uneven temperature | Stir continuously |
Risk assessment
| Hazard | Risk | Control measure |
|---|---|---|
| Hot water | Scalds | Handle carefully |
| Electricity near water | Shock | Low-voltage supply; keep connections dry |
Common mistakes
- Measuring across the wrong component.
- Assuming the calibration is linear.
- Not waiting for thermal equilibrium.
Worked analysis
At 40 °C the thermistor is 2.2 kΩ. \(V_{\text{out}}\) = \(\dfrac{6.0 \times 2.2}{2.2 + 2.2}\) = 3.0 V across the fixed resistor.
Common misconception
An NTC thermistor's resistance decreases as temperature increases; the output rises across the fixed resistor, not across the thermistor.
Assessment coverage
Practice this practical
2 questions available, worth 4 marks in total.
Retrieval cards
How does an NTC thermistor behave?
Resistance falls as temperature rises.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
This card is available with A-Level Physics premium access.
How this practical fits your course
The label below uses the wording from your course specification.
- OCR H556 — Suggested PAG activity: PAG 4 – Investigating electrical circuits / example: potential divider circuits. OCR requires PAG 4 construction, design and checking of d.c. circuits; investigation of potential-divider circuits is the specification example and the shared resource includes both fixed-resistor and sensor dividers. Checked 18 September 2026. View official course source